Multi-Conductor Cables
16 Channel, multi-conductor cables are shielded and wired for PCB® equipment specifically. Shielding minimizes noise when located near other power or signal cables. Custom versions are also available on request. Instrumentation-grade BNC / DB-50 connectors are provided to interface with Patch Panels and Signal Conditioners.
Multi-Conductor Cables
|
|
|
|
|
|
Model
|
009A05
|
009A10
|
009A25
|
009H50
|
Cable Style
|
Multi-Conductor - Ruggedized
|
Multi-Conductor - Ruggedized
|
Multi-Conductor - Ruggedized
|
Multi-Conductor - Ribbon
|
Description
|
Multi-conductor shielded cable, ruggedized, 5-ft, DB50 female to (16) BNC plugs (Wired for PCB equipment ONLY)
|
Multi-conductor shielded cable, ruggedized, 10-ft, DB50 female to (16) BNC plugs (Wired for PCB equipment ONLY)
|
Multi-conductor shielded cable, ruggedized, 25-ft, DB50 female to (16) BNC plugs (Wired for PCB equipment ONLY)
|
Multi-conductor, shielded flat ribbon cable, 50-ft, DB50 female to DB50 male (Wired for PCB equipment ONLY)
|
Jacket Material
|
PVC
|
PVC
|
PVC
|
PVC
|
Jacket Pros
|
Extremely flexible
|
Extremely flexible
|
Extremely flexible
|
Flexible flat profile
|
Jacket Cons
|
Large diameter multichannel
|
Large diameter multichannel
|
Large diameter multichannel
|
Limited impact resistance
|
Type of Use
|
Patch Panel or DAQ
|
Patch Panel or DAQ
|
Patch Panel or DAQ
|
Gender Changer
|
Connector 1
|
DB50 female
|
DB50 female
|
DB50 female
|
DB50 female
|
Connector 2
|
BNC Plug x 16
|
BNC Plug x 16
|
BNC Plug x 16
|
DB50 male
|
Length
|
5 ft (1.5 m)
|
10 ft (3 m)
|
10 ft (7.6 m)
|
50 ft (15.3 m)
|
Temperature Range
|
-31 to 167 °F
35 to +75 °C
|
-31 to 167 °F
35 to +75 °C
|
-31 to 167 °F
35 to +75 °C
|
-31 to 221 °F
-35 to +105 °C
|
Nominal Cable Size
|
Diameter 0.63 in (16 mm)
|
Diameter 0.63 in (16 mm)
|
Diameter 0.63 in (16 mm)
|
Thickness 0.12 in (2.9 mm)
|
Bend Radius
|
6.5 in (16.5 cm)
|
6.5 in (16.5 cm)
|
6.5 in (16.5 cm)
|
–
|
Cable Bulk Weight
|
225 lbs per 1000 ft
|
225 lbs per 1000 ft
|
225 lbs per 1000 ft
|
–
|
Center Conductor Style
|
Stranded, shielded twisted pair
|
Stranded, shielded twisted pair
|
Stranded, shielded twisted pair
|
Stranded, shielded ribbon
|
Center Conductor Material
|
Tinned Copper
|
Tinned Copper
|
Tinned Copper
|
Tinned Copper
|
Conductor Size, braid
|
24 AWG, 7 x 32
|
24 AWG, 7 x 32
|
24 AWG, 7 x 32
|
24 AWG, 7 x 36
|
Shield Type Coverage
|
Braided with drain as pair and outer shield
|
Braided with drain as pair and outer shield
|
Braided with drain as pair and outer shield
|
Dual Drain + Foil
|
Full specifications
|
009A05
|
009A10
|
009A25
|
009H50
|