Model: 3501A2060KG

$690.00 USD
(Pricing valid in US only)

Datasheet

Shock accelerometer, 60 kg, MEMS sensor installed in chip carrier (SMT)

  • Sensitivity: (±50%) .003 mV/g (.0003 mV/(m/s²))
  • Measurement Range: ±60000 g (±588400 m/s² pk)
  • Frequency Range: (1dB) 0 to 20000 Hz
  • Sensing Geometry: Full Active
  • Mounting: Surface Mount

Add this product to my product comparison
Compare selected models ()

 English:SI: 
Performance
Sensitivity (±50 %) (at 10 VDC excitation).003 mV/g.0003 mV/(m/s²)[2] 
Sensitivity0.0003 mV/V/g0.00003 mV/V/(m/s²)[3] 
Measurement Range±60000 g±588400 m/s² pk 
Frequency Range (1 dB)0 to 20000 Hz0 to 20000 Hz 
Resonant Frequency>120 kHz>120 kHz 
Damping Ratio2 % Critical2 % Critical[1] 
Non-Linearity (per 10,000 g (98,100 m/s²))±1 %±1 % 
Transverse Sensitivity≤3 %≤3 % 
Environmental
Overload Limit (Shock)±100000 g pk±980665 m/s² pk[5] 
Overload Limit (Mechanical Stops)≥80000 g≥782534 m/s² pk 
Temperature Range (Storage)-65 to 250 °F-54 to 121 °C 
Temperature Coefficient of Sensitivity-0.11 %/°F-0.20 %/°C[1] 
Zero g Offset Temperature Shift±10 mV±10 mV[4] 
Base Strain Sensitivity0.3 g/µε2.94 (m/s²)/µε[1] 
Electrical
Excitation Voltage (Maximum)15.0 VDC15.0 VDC 
Current Consumption<3 mA<3 mA 
Input Resistance (±2000 Ohm)6000 Ohm6000 Ohm[2] 
Output Resistance (±2000 Ohm)6000 Ohm6000 Ohm[2] 
Offset Voltage-40 to +40 mVDC-40 to +40 mVDC[2] 
Settling Time0.01 sec0.01 sec[6] 
Physical
Sensing ElementPiezoresistive MEMSPiezoresistive MEMS 
Sensing GeometryFull ActiveFull Active 
Housing MaterialCeramicCeramic 
SealingEpoxyEpoxy 
Size - Height0.085 in2.16 mm 
Size - Length0.236 in6.00 mm 
Size - Width0.138 in3.50 mm 
Weight0.005 oz0.15 gm[1] 
Electrical ConnectorSolder TabsSolder Tabs 
MountingSurface MountSurface Mount 

All specifications are at room temperature unless otherwise specified.


CE

Product Notes
[1] Typical.
[2] Verified with test data provided on supplied calibration certificate.
[3] Sensitivity is proportional to excitation voltage, and at other excitation values, sensitivity can be predicted from the 10VDC calibrated value with a small (<~.5%) increase in uncertainty.
[4] -65 to +250 °F, ref. 75 °F (-54 to +121 °C, ref. 24 °C)
[5] Half-sine pulse duration, >= 20 µsec.
[6] Settling Time is the maximum time after power-up for the Offset Voltage to be within +/-2% of Measurement Range output of the final offset value. Mounting surface must be at thermal equilibrium.
[7] See PCB Declaration of Conformance PS151 for details.
Accessories:
Supplied
ACS-62Shock Pulse Calibration of single axis piezoresistive shock accelerometer to maximum amplitude of 5k g, 10.0 VDC excitation(1)
Optional Versions:
No optional versions
Product Documents
Additional Downloads