Multi-Conductor Cables

16 Channel, multi-conductor cables are shielded and wired for PCB® equipment specifically. Shielding minimizes noise when located near other power or signal cables. Custom versions are also available on request. Instrumentation-grade BNC / DB-50 connectors are provided to interface with Patch Panels and Signal Conditioners.

Multi-Conductor Cables

 

Model

009A05

009A10

009A25

009H50

Cable Style

Multi-Conductor - Ruggedized

Multi-Conductor - Ruggedized

Multi-Conductor - Ruggedized

Multi-Conductor - Ribbon

Description

Multi-conductor shielded cable, ruggedized, 5-ft, DB50 female to (16) BNC plugs (Wired for PCB equipment ONLY)

Multi-conductor shielded cable, ruggedized, 10-ft, DB50 female to (16) BNC plugs (Wired for PCB equipment ONLY)

Multi-conductor shielded cable, ruggedized, 25-ft, DB50 female to (16) BNC plugs (Wired for PCB equipment ONLY)

Multi-conductor, shielded flat ribbon cable, 50-ft, DB50 female to DB50 male (Wired for PCB equipment ONLY)

Jacket Material

PVC

PVC

PVC

PVC

Jacket Pros

Extremely flexible

Extremely flexible

Extremely flexible

Flexible flat profile

Jacket Cons

Large diameter multichannel

Large diameter multichannel

Large diameter multichannel

Limited impact resistance

Type of Use

Patch Panel or DAQ

Patch Panel or DAQ

Patch Panel or DAQ

Gender Changer

Connector 1

DB50 female

DB50 female

DB50 female

DB50 female

Connector 2

BNC Plug x 16

BNC Plug x 16

BNC Plug x 16

DB50 male

Length

5 ft
(1.5 m)

10 ft
(3 m)

10 ft
(7.6 m)

50 ft
(15.3 m)

Temperature Range

-31 to 167 °F
35 to +75 °C

-31 to 167 °F
35 to +75 °C

-31 to 167 °F
35 to +75 °C

-31 to 221 °F
-35 to +105 °C

Nominal Cable Size

Diameter 0.63 in
(16 mm)

Diameter 0.63 in
(16 mm)

Diameter 0.63 in
(16 mm)

Thickness 0.12 in
(2.9 mm)

Bend Radius

6.5 in
(16.5 cm)

6.5 in
(16.5 cm)

6.5 in
(16.5 cm)

Cable Bulk Weight

225 lbs per 1000 ft

225 lbs per 1000 ft

225 lbs per 1000 ft

Center Conductor Style

Stranded, shielded twisted pair

Stranded, shielded twisted pair

Stranded, shielded twisted pair

Stranded, shielded ribbon

Center Conductor Material

Tinned Copper

Tinned Copper

Tinned Copper

Tinned Copper

Conductor Size, braid

24 AWG, 7 x 32

24 AWG, 7 x 32

24 AWG, 7 x 32

24 AWG, 7 x 36

Shield Type Coverage

Braided with drain as pair and outer shield

Braided with drain as pair and outer shield

Braided with drain as pair and outer shield

Dual Drain + Foil

Full specifications

009A05

009A10

009A25

009H50