Model: 350B43

$2,730.00 USD
(Pricing valid in US only)

Datasheet

ICP® Triaxial shock accelerometer, 0.5 mV/g, 10k g range, mechanically isolated and electrically filtered, 5-ft integral cable

  • Sensitivity: (±30%) 0.5 mV/g (0.05 mV/(m/s²))
  • Measurement Range: ±10000 g pk (±98000 m/s² pk)
  • Frequency Range: (±1dB) 0.4 to 10000 Hz
  • Electrical Connector: Integral Cable (Integral Cable)

Add this product to my product comparison
Compare selected models ()

 English:SI: 
Performance
Sensitivity (±30 %)0.5 mV/g0.05 mV/(m/s²) 
Measurement Range±10000 g pk±98000 m/s² pk 
Frequency Range (±1 dB)0.4 to 10000 Hz0.4 to 10000 Hz 
Frequency Range (-3 dB)0.2 to 25000 Hz0.2 to 25000 Hz[2] 
Resonant Frequency>50 kHz>50 kHz 
Electrical Filter Corner Frequency (3 dB)21 kHz21 kHz[1][3] 
Mechanical Filter Resonant Frequency35 kHz35 kHz[1][4] 
Broadband Resolution (1 to 10000 Hz)0.04 g rms0.39 m/s² rms[1] 
Non-Linearity (per 1000 g (9810 m/s2))2.0 %2.0 % 
Transverse Sensitivity≤7 %≤7 % 
Environmental
Overload Limit (Shock)±50000 g pk±490000 m/s² pk 
Temperature Range (Operating)-10 to +150 °F-23 to +66 °C 
Temperature Range (Storage)-40 to +200 °F-40 to +93 °C 
Temperature ResponseSee Graph %/°FSee Graph %/°F[1][5] 
Base Strain Sensitivity0.002 g/µε0.02 (m/s²)/µε[1] 
Electrical
Excitation Voltage20 to 30 VDC20 to 30 VDC 
Constant Current Excitation2 to 20 mA2 to 20 mA 
Output Impedance≤200 Ohm≤200 Ohm 
Output Bias Voltage8 to 14 VDC8 to 14 VDC 
Discharge Time Constant1.0 to 2.0 sec1.0 to 2.0 sec[1] 
Settling Time (within 10% of bias)<10 sec<10 sec 
Electrical Isolation (Case)>100000000 Ohm>100000000 Ohm 
Physical
Sensing ElementCeramicCeramic 
Sensing GeometryShearShear 
Housing MaterialTitaniumTitanium 
SealingHermeticHermetic 
Size - Height1.02 in26.0 mm 
Size - Length1.02 in26.0 mm 
Size - Width1.02 in26.0 mm 
Weight (without cable)0.95 oz27 g[1] 
Electrical ConnectorIntegral Cable Integral Cable  
Electrical Connection PositionSideSide 
Cable Termination1/4-28 4-Pin Jack1/4-28 4-Pin Jack 
Cable Length5.0 ft1.52 m 
Cable Type034 4-cond Shielded034 4-cond Shielded 
MountingThrough HoleThrough Hole 

All specifications are at room temperature unless otherwise specified.


CE

Product Notes
[1] Typical.
[2] Typical corner frequency for coupled electrical and mechanical filters.
[3] Electrical filter is a second order filter.
[4] Amplitude at resonance is +9 dB.
[5] Test performed on a shaker at 100Hz
[6] See PCB Declaration of Conformance PS023 for details.
Accessories:
Supplied
034G05(1)
100-16040-40Metric mounting screws (M6x1.0 x 22mm long(1)
100-6774-10STD mounting screw (1/4-28 x .87 long)(1)
100-8994-40Coupling grease(1)
ACS-14THigh G shock triaxial accelerometer calibration using Hopkinson bar(1)
ACS-22TNIST Traceable triaxial frequency response (100Hz to ±1 Db point(1)
Optional Versions:
No optional versions
Product Documents