**DO NOT SELL** ICP® Triaxial shock accelerometer, 0.5 mV/g, 10k g range, mechanically isolated and electrically filtered, 5-ft integral cable
No longer in production,current model is 350B43
|
English: |
SI: |
|
Performance |
Sensitivity (±30 %) |
0.5 mV/g |
0.05 mV/(m/s²) |
|
Measurement Range |
±10000 g pk |
±98000 m/s² pk |
|
Frequency Range (±1 dB) |
0.4 to 10000 Hz |
0.4 to 10000 Hz |
|
Frequency Range (-3 dB) |
0.2 to 25000 Hz |
0.2 to 25000 Hz |
[
2]
|
Resonant Frequency |
>50 kHz |
>50 kHz |
|
Electrical Filter Corner Frequency (3) |
21 kHz |
21 kHz |
[
1]
[
3]
|
Mechanical Filter Resonant Frequency |
35 kHz |
35 kHz |
[
1]
[
4]
|
Broadband Resolution (1) |
0.04 g rms |
0.39 m/s² rms |
[
1]
|
Non-Linearity (per 1000 g (9810 m/s2)) |
≤2.0 % |
≤2.0 % |
|
Transverse Sensitivity |
≤7 % |
≤7 % |
|
Environmental |
Overload Limit (Shock) |
±50000 g pk |
±490000 m/s² pk |
|
Temperature Range (Operating) |
0 to +150 °F |
-18 to +66 °C |
|
Temperature Range (Storage) |
-40 to +200 °F |
-40 to +93 °C |
|
Temperature Response |
See Graph %/°F |
See Graph %/°F |
[
1]
|
Base Strain Sensitivity |
0.002 g/µε |
0.02 (m/s²)/µε |
[
1]
|
Electrical |
Excitation Voltage |
20 to 30 VDC |
20 to 30 VDC |
|
Constant Current Excitation |
2 to 20 mA |
2 to 20 mA |
|
Output Impedance |
≤200 Ohm |
≤200 Ohm |
|
Output Bias Voltage |
8 to 14 VDC |
8 to 14 VDC |
|
Discharge Time Constant |
1.0 to 2.0 sec |
1.0 to 2.0 sec |
[
1]
|
Settling Time (within 10% of bias) |
<10 sec |
<10 sec |
|
Electrical Isolation (Case) |
>100000000 Ohm |
>100000000 Ohm |
|
Physical |
Sensing Element |
Ceramic |
Ceramic |
|
Sensing Geometry |
Shear |
Shear |
|
Housing Material |
Titanium |
Titanium |
|
Sealing |
Hermetic |
Hermetic |
|
Size - Height |
1.02 in |
26.0 mm |
|
Size - Length |
1.02 in |
26.0 mm |
|
Size - Width |
1.02 in |
26.0 mm |
|
Weight (without cable) |
2.20 oz |
62.5 g |
[
1]
|
Electrical Connector |
Integral Cable |
Integral Cable |
|
Electrical Connection Position |
Side |
Side |
|
Cable Termination |
1/4-28 4-Pin Jack |
1/4-28 4-Pin Jack |
|
Cable Length |
5.0 ft |
1.52 m |
|
Cable Type |
034 4-cond Shielded |
034 4-cond Shielded |
|
Mounting |
Through Hole |
Through Hole |
|
* All specifications are at room temperature unless otherwise specified
.

Specification Notes
[
1]
Typical.
[
2]
Typical corner frequency for coupled electrical and mechanical filters.
[
3]
Electrical filter is a second order filter.
[
4]
Amplitude at resonance is +9 dB.
[
1]
Typical.
[
5]
See PCB Declaration of Conformance PS023 for details.
Accessories
|
|
|
Supplied |
034G05 |
4-conductor, low noise, shielded FEP cable, 5-ft, 4-socket plug to (3) BNC plugs (labeled X Y Z) |
1 |
100-8994-40 |
|
1 |
ACS-14T |
|
1 |
ACS-22T |
Triaxial amplitude response calibration for shock accelerometer, 100 Hz to upper 1 dB frequency (max 15 kHz) |
1 |
100-15136-80 |
|
2 |
100-8360-70 |
|
2 |