Model : 350A43 | Triaxial ICP® Shock Accelerometer

Click for lead times

**DO NOT SELL** ICP® Triaxial shock accelerometer, 0.5 mV/g, 10k g range, mechanically isolated and electrically filtered, 5-ft integral cable

No longer in production,current model is 350B43

    English: SI:
    Performance
    Sensitivity (±30 %) 0.5 mV/g 0.05 mV/(m/s²)
    Measurement Range ±10000 g pk ±98000 m/s² pk
    Frequency Range (±1 dB) 0.4 to 10000 Hz 0.4 to 10000 Hz
    Frequency Range (-3 dB) 0.2 to 25000 Hz 0.2 to 25000 Hz [2]
    Resonant Frequency >50 kHz >50 kHz
    Electrical Filter Corner Frequency (3) 21 kHz 21 kHz [1] [3]
    Mechanical Filter Resonant Frequency 35 kHz 35 kHz [1] [4]
    Broadband Resolution (1) 0.04 g rms 0.39 m/s² rms [1]
    Non-Linearity (per 1000 g (9810 m/s2)) ≤2.0 % ≤2.0 %
    Transverse Sensitivity ≤7 % ≤7 %
    Environmental
    Overload Limit (Shock) ±50000 g pk ±490000 m/s² pk
    Temperature Range (Operating) 0 to +150 °F -18 to +66 °C
    Temperature Range (Storage) -40 to +200 °F -40 to +93 °C
    Temperature Response See Graph %/°F See Graph %/°F [1]
    Base Strain Sensitivity 0.002 g/µε 0.02 (m/s²)/µε [1]
    Electrical
    Excitation Voltage 20 to 30 VDC 20 to 30 VDC
    Constant Current Excitation 2 to 20 mA 2 to 20 mA
    Output Impedance ≤200 Ohm ≤200 Ohm
    Output Bias Voltage 8 to 14 VDC 8 to 14 VDC
    Discharge Time Constant 1.0 to 2.0 sec 1.0 to 2.0 sec [1]
    Settling Time (within 10% of bias) <10 sec <10 sec
    Electrical Isolation (Case) >100000000 Ohm >100000000 Ohm
    Physical
    Sensing Element Ceramic Ceramic
    Sensing Geometry Shear Shear
    Housing Material Titanium Titanium
    Sealing Hermetic Hermetic
    Size - Height 1.02 in 26.0 mm
    Size - Length 1.02 in 26.0 mm
    Size - Width 1.02 in 26.0 mm
    Weight (without cable) 2.20 oz 62.5 g [1]
    Electrical Connector Integral Cable Integral Cable
    Electrical Connection Position Side Side
    Cable Termination 1/4-28 4-Pin Jack 1/4-28 4-Pin Jack
    Cable Length 5.0 ft 1.52 m
    Cable Type 034 4-cond Shielded 034 4-cond Shielded
    Mounting Through Hole Through Hole
    * All specifications are at room temperature unless otherwise specified
    .


    Specification Notes


    [1] Typical.
    [2] Typical corner frequency for coupled electrical and mechanical filters.
    [3] Electrical filter is a second order filter.
    [4] Amplitude at resonance is +9 dB.
    [1] Typical.
    [5] See PCB Declaration of Conformance PS023 for details.


    Accessories


    Supplied
    034G05 4-conductor, low noise, shielded FEP cable, 5-ft, 4-socket plug to (3) BNC plugs (labeled X Y Z) 1
    100-8994-40 1
    ACS-14T 1
    ACS-22T Triaxial amplitude response calibration for shock accelerometer, 100 Hz to upper 1 dB frequency (max 15 kHz) 1
    100-15136-80 2
    100-8360-70 2