PCB L&T S-Type Load Cell, 5,000 lbf rated capacity, 150% of RO static overload protection, 2mV/V output, 5/8-18 UNF threads, integral 10 ft cable w/ open end, nickel-plated steel
- Measurement Range: 5000 lb
(22.2 kN)
- Size - Height: 3.50 in
(89 mm)
- Electrical Connector: 10 ft - Integrated Cable
|
English: |
SI: |
|
Performance |
Measurement Range |
5000 lb |
22.2 kN |
[1]
|
Sensitivity (±10 %) |
2 mV/V |
2 mV/V |
[2]
|
Non-Linearity |
≤0.05 % FS |
≤0.05 % FS |
|
Hysteresis |
≤0.03 % FS |
≤0.03 % FS |
|
Non-Repeatability |
≤0.02 %RO |
≤0.02 %RO |
|
Creep (in 20 minutes) |
≤0.08 % |
≤0.08 % |
|
Resonant Frequency |
2.5 kHz |
2.5 kHz |
|
Environmental |
Overload Limit |
7500 lb |
33.4 kN |
|
Load Limit (Side Force, FX or FY) |
500 lb |
2224 N |
[3]
|
Load Limit (Bending Moment, MX or MY) |
1250 in-lb |
141.2 Nm |
[3]
|
Load Limit (Axial Torque, MZ) |
1250 in-lb |
141.2 Nm |
[3]
|
Temperature Range (Operating) |
0 to +200 °F |
-18 to +93 °C |
|
Temperature Range (Compensated) |
+70 to +170 °F |
+21 to +77 °C |
|
Temperature Effect on Output (Maximum) |
±0.0008 %Reading/°F |
±0.0015 %Reading/°C |
[4]
|
Temperature Effect on Zero Balance (Maximum) |
±0.0015 %FS/°F |
±0.027 %FS/°C |
[4]
|
Electrical |
Bridge Resistance |
350 Ohm |
350 Ohm |
[5]
|
Excitation Voltage (Recommended) |
10 VDC |
10 VDC |
[6]
|
Insulation Resistance |
>5000000000 Ohm |
>5000000000 Ohm |
|
Zero Balance |
±1 % FS |
±1 % FS |
|
Output Polarity |
+Tension |
+Tension |
|
Physical |
Size - Height |
3.50 in |
89 mm |
|
Size - Width |
1.50 in |
38 mm |
|
Size - Length |
2.50 in |
64 mm |
[7]
|
Weight |
2.85 lb |
1.3 g |
|
Mounting Thread |
5/8-18 Thread |
No Metric Equivalent |
|
Housing Material |
Nickel Plated Steel |
Nickel Plated Steel |
|
Sensing Element |
Strain Gage |
Strain Gage |
|
Deflection at Full Scale Capacity |
0.003 in |
0.05 mm |
|
Electrical Connector |
10 ft - Integrated Cable |
10 ft - Integrated Cable |
|
Electrical Connection Position |
Side |
Side |
|
* All specifications are at room temperature unless otherwise specified
.
Specification Notes
[1] FS - Full Scale.
[2] RO - Rated Output.
[3] Singularly applied, i.e. no other extraneous loads.
[4] Over compensated operating temperature range.
[5] Nominal.
[6] Calibrated at 10 VDC, usable 5 to 20 VDC or VAC RMS.
[7] See Outline Drawing 46138 for Complete Dimensions