Model : 350B50 | Accelerometer, ICP®, Triaxial

Click for lead times
Lead Time for 1-5 is 8 Wks
Lead Time for 6-10 is 9 Wks
$ 2,127.00 USD
(Pricing valid in US only!)

High amplitude, triaxial ICP® accel., 0.5 mV/g, 10k g range, w/built-in 2nd order low-pass filter (-3dB at 20 kHz)

  • Sensitivity: (±30%)0.5 mV/g (0.05 mV/(m/s²))
  • Measurement Range: ±10000 g pk (±98000 m/s² pk)
  • Electrical Connector: Integral Cable

RELATED PRODUCTS



350B50/NC

High amplitude, triaxial ICP® accel., 0.5 mV/g, 10k g range, w/built-in 2nd order low-pass filter (-3dB at 20 kHz), no mating cable supplied



Add to Cart for Quote
Add To Cart
080A197

Mounting Adaptor, through hole for 350B50



Add to Cart for Quote
Add To Quote
English: SI:
Performance
Sensitivity (±30 %) 0.5 mV/g 0.05 mV/(m/s²)
Measurement Range ±10000 g pk ±98000 m/s² pk
Frequency Range (±1 dB) 3 to 10000 Hz 3 to 10000 Hz
Frequency Range (-3 dB) 1.5 to 20000 Hz 1.5 to 20000 Hz [3]
Resonant Frequency ≥60 kHz ≥60 kHz
Broadband Resolution (1) 0.03 g rms 0.29 m/s² rms [2]
Non-Linearity (per 1000 g (9810 m/s2)) ≤2 % ≤2 % [1]
Transverse Sensitivity ≤5 % ≤5 %
Environmental
Overload Limit (Shock) ±25000 g pk ±245000 m/s² pk
Temperature Range (Operating) -65 to +250 °F -54 to +121 °C
Temperature Response See Graph %/°F See Graph %/°F [2]
Electrical
Excitation Voltage 18 to 30 VDC 18 to 30 VDC
Constant Current Excitation 2 to 20 mA 2 to 20 mA
Output Impedance ≤100 Ohm ≤100 Ohm
Output Bias Voltage 8 to 12 VDC 8 to 12 VDC
Discharge Time Constant 0.5 to 1.0 sec 0.5 to 1.0 sec
Settling Time (within 10% of bias) <5 sec <5 sec
Electrical Isolation (Base) >100000000 Ohm >100000000 Ohm
Physical
Sensing Element Ceramic Ceramic
Sensing Geometry Shear Shear
Housing Material Titanium Titanium
Sealing Hermetic Hermetic
Size - Height 0.32 in 8.2 mm
Size - Length 0.72 in 18.3 mm
Size - Width 0.72 in 18.3 mm
Weight (without cable) 0.3 oz 8.0 gm [2]
Electrical Connector Integral Cable Integral Cable
Electrical Connection Position Side Side
Cable Termination 1/4-28 4-Pin Jack 1/4-28 4-Pin Jack
Cable Length 5.0 ft 1.52 m
Cable Type 034 4-cond Shielded 034 4-cond Shielded
Mounting Through Hole Through Hole
* All specifications are at room temperature unless otherwise specified
.


Specification Notes


[1] Zero-based, least-squares, straight line method.
[2] Typical.
[3] Electrical filter is a second order filter.
[2] Typical.
[4] See PCB Declaration of Conformance PS023 for details.


Accessories


Supplied
034G05 4-conductor, low noise, shielded FEP cable, 5-ft, 4-socket plug to (3) BNC plugs (labeled X Y Z) 1
080A197 Mounting Adaptor, through hole for 350B50 1
080B197 Mounting Adaptor, through hole for 350B50 1
ACS-14T 1
ACS-22T Triaxial amplitude response calibration for shock accelerometer, 100 Hz to upper 1 dB frequency (max 15 kHz) 1
081A112 Socket head cap screw assembly, 6-32 thread with off ground washer and tube 4