High frequency ICP® pressure sensor, 100 psi, 50 mV/psi, 0.218" dia. diaphragm, accel. comp.
- Measurement Range: 100 psi
(689.4 kPa)
- Sensitivity: (±15%)50 mV/psi
(7.25 mV/kPa)
- Low Frequency Response: (-5%)0.5 Hz
- Resonant Frequency: >=500 kHz
(>=500 kHz)
- Electrical Connector: 10-32 Coaxial Jack
- Weight: 0.16 oz
(4.5 gm)
RELATED PRODUCTS
|
English: |
SI: |
|
Performance |
Measurement Range (for ±5V output) |
100 psi |
689.4 kPa |
|
Useful Overrange (for ± 10V output) |
200 psi |
1378.8 kPa |
[3]
|
Sensitivity (±15 %) |
50 mV/psi |
7.25 mV/kPa |
|
Maximum Pressure |
1000 psi |
6895 kPa |
|
Resolution |
0.001 psi |
0.007 kPa |
[2]
|
Resonant Frequency |
≥500 kHz |
≥500 kHz |
|
Rise Time |
≤1.0 µ sec |
≤1.0 µ sec |
|
Low Frequency Response (-5 %) |
0.5 Hz |
0.5 Hz |
|
Non-Linearity |
≤1.0 % FS |
≤1.0 % FS |
[1]
|
Environmental |
Acceleration Sensitivity |
≤0.002 psi/g |
≤0.0014 kPa/(m/s²) |
|
Temperature Range (Operating) |
-100 to +275 °F |
-73 to +135 °C |
|
Temperature Coefficient of Sensitivity |
≤0.03 %/°F |
≤0.054 %/°C |
[2]
|
Maximum Flash Temperature |
3000 °F |
1649 °C |
|
Maximum Vibration |
2000 g pk |
19614 m/s² pk |
|
Maximum Shock |
20000 g pk |
196140 m/s² pk |
|
Electrical |
Output Polarity (Positive Pressure) |
Positive |
Positive |
|
Discharge Time Constant (at room temp) |
≥1.0 sec |
≥1.0 sec |
|
Excitation Voltage |
20 to 30 VDC |
20 to 30 VDC |
|
Constant Current Excitation |
2 to 20 mA |
2 to 20 mA |
|
Output Impedance |
<100 Ohm |
<100 Ohm |
|
Output Bias Voltage |
8 to 14 VDC |
8 to 14 VDC |
|
Physical |
Sensing Geometry |
Compression |
Compression |
|
Sensing Element |
Quartz |
Quartz |
|
Housing Material |
17-4 Stainless Steel |
17-4 Stainless Steel |
|
Diaphragm |
Invar |
Invar |
|
Sealing |
Welded Hermetic |
Welded Hermetic |
|
Electrical Connector |
10-32 Coaxial Jack |
10-32 Coaxial Jack |
|
Weight (with clamp nut) |
0.16 oz |
4.5 gm |
|
* All specifications are at room temperature unless otherwise specified
.

Specification Notes
[1] Zero-based, least-squares, straight line method.
[2] Typical.
[3] For +10 volt output, minimum 24 VDC supply voltage required. Negative 10 volt output may be limited by output bias.
[2] Typical.
[4] See PCB Declaration of Conformance PS023 for details.
Accessories
|
|
|
Supplied |
060A03 |
Clamp nut, 5/16-24-2A thd, 1/4" hex, SS (for Series 111, 112 & 113) |
1 |
060A05 |
Clamp nut, M7 x 0.75-6G thd (for Series M111, M112 & M113) |
1 |
065A05 |
Seal sleeve, sensor recess mount, 0.248" OD x 0.221" ID x 0.240" thk, 17-4 SS (for Series 111A, 112A & 113A) |
1 |
065A02 |
Seal ring, sensor flush mount, 0.248" OD x 0.219" ID x 0.015" thk, brass (for Series 111A, 112A & 113A) |
3 |
Optional Versions
( E ) Emralon coating
Electrical Isolation |
100000000 Ohm |
Coating |
Emralon |
( S ) Stainless Steel Diaphragm
( W ) Water Resistant Cable
Accessories: |
Supplied |
060A03 |
Clamp nut, 5/16-24-2A thd, 1/4" hex, stainless steel |
1 |
( WM ) Water Resistant Cable
Accessories: |
Supplied |
060A05 |
Clamp nut M7 x 0.75-6g thd |
1 |