Log In

Log In

Need an Account? Start Here

 

Model: HT602D61

Add to Cart for Quote
Datasheet

Low profile, industrial, ceramic shear ICP® accel., 100 mV/g, 0.4 to 8000 Hz, side exit, 10-ft integral armor cable, High Temp option

Capable of withstanding continuous temperatures of 325 °F (162 °C) without decay in performance, higher than any other IEPE accelerometer in the industry.

  • Sensitivity: (±10%) 100 mV/g (10.2 mV/(m/s²))
  • Frequency Range: (±3dB) 48 to 480000 cpm (0.8 to 8000 Hz)
  • Sensing Element: Ceramic
  • Measurement Range: ±50 g (±490 m/s²)
  • Weight: 5.4 oz (153 gm)

Add this product to my product comparison
Compare selected models ()

 English:SI: 
Performance
Sensitivity (±10 %)100 mV/g10.2 mV/(m/s²)[1] 
Measurement Range±50 g±490 m/s² 
Frequency Range (±3 dB)48 to 480000 cpm0.8 to 8000 Hz[4][5] 
Resonant Frequency1500 kcpm25 kHz[2] 
Broadband Resolution (1 to 10 kHz)150 µg1472 µm/sec2[2] 
Non-Linearity±1 %±1 %[3] 
Transverse Sensitivity≤5 %≤5 % 
Environmental
Overload Limit (Shock)5000 g pk49050 m/s² pk 
Temperature Range-65 to 325 °F-54 to 162 °C 
Temperature ResponseSee Graph %/°FSee Graph %/°F[2] 
Enclosure RatingIP67IP67 
Electrical
Settling Time (within 1% of bias)≤2.0 sec≤2.0 sec 
Discharge Time Constant≥0.2 sec≥0.2 sec 
Excitation Voltage18 to 28 VDC18 to 28 VDC 
Constant Current Excitation2 to 20 mA2 to 20 mA 
Output Impedance<150 Ohm<150 Ohm 
Output Bias Voltage8 to 12 VDC8 to 12 VDC 
Spectral Noise (10 Hz)9.0 µg/√Hz88.3 (µm/sec2)/√Hz[2] 
Spectral Noise (100 Hz)4.0 µg/√Hz39.2 (µm/sec2)/√Hz[2] 
Spectral Noise (1 kHz)2.0 µg/√Hz19.6 (µm/sec2)/√Hz[2] 
Electrical Isolation>100000000 Ohm>100000000 Ohm 
Physical
Size - Length2.1 in53.3 mm 
Size - Width1.0 in25.4 mm 
Size - Height1.0 in25.4 mm 
Weight (without cable)5.4 oz153 gm 
Mounting Torque2 to 5 ft-lb2.7 to 6.8 Nm 
Sensing ElementCeramicCeramic 
Sensing GeometryShearShear 
Housing MaterialStainless SteelStainless Steel 
Electrical ConnectorIntegral Armored CableIntegral Armored Cable 
Electrical Connection PositionSideSide 
Cable TerminationBlunt cutBlunt cut 
Electrical Connections (White )Signal / PowerSignal / Power 
Electrical Connections (Black )GroundGround 
Cable Length10 ft3.0 m 
Cable Type055 2-cond shielded with FEP jacket in 5/16" armor055 2-cond shielded with FEP jacket in 5/16" armor 

All specifications are at room temperature unless otherwise specified.


CE

Product Notes
[1] Conversion Factor 1g = 9.81 m/s².
[2] Typical.
[3] Zero-based, least-squares, straight line method.
[4] 1Hz = 60 cpm (cycles per minute).
[5] The high frequency tolerance is accurate within ±10% of the specified frequency.
[6] See PCB Declaration of Conformance PS023 for details.
Accessories:
Supplied
081A73Captive mounting bolt 1/4-28 x 1.34"(1)
Optional Versions:
(M) Metric Mount
 ENGLISHSI
Accessories:
    M081A73Captive Mounting Bolt(1)
Product Documents
Additional Downloads