intrinsically-safe, low profile industrial icp® accel, 100 mv/g, 0.5 to 10k hz, side exit, integral cable & swiveler base, single point iso 17025 accredited calibration

ACCELEROMETER

Model EX607A11

Retrieving Price...

(Pricing valid only in the U.S.)

Units in Stock Lead Times
1 Call for Lead Time
  • CE
  • EX
  • IP

Intrinsically-safe, low profile industrial ICP® accel, 100 mV/g, 0.5 to 10k Hz, side exit, integral cable & swiveler base, single point ISO 17025 accredited calibration

Harardous area approved low profile industrial ICP® accel, 100 mV/g, 0.5 to 10k Hz, side exit, 10-ft integral cable

    Additional configurations:

    Specification Notes


    [1] Conversion Factor 1g = 9.81 m/s².
    [2] Zero-based, least-squares, straight line method.
    [3] Typical.
    [4] Twisted shielded pair.
    [5] 1/4-28 has no equivalent in S.I. units.
    [6] Stud torque must exceed sensor hex nut torque to ensure proper dismantling.
    [7] 1/8" hex Allen key required for English version, 4 mm hex Allen key required for Metric version.
    [8] Measured with mounting stud.
    [9] See PCB Declaration of Conformance PS023 or PS060 for details.

    English: SI:
    Performance
    Sensitivity (±15 %) 100 mV/g 10.2 mV/(m/s²) [1]
    Measurement Range ±50 g ±490 m/s²
    Frequency Range (±3 dB) 30 to 600000 cpm 0.5 to 10000 Hz
    Resonant Frequency 1500 kcpm 25 kHz [3]
    Broadband Resolution (1) 350 µg 3434 µm/sec2 [3]
    Non-Linearity ±1 % ±1 % [2]
    Transverse Sensitivity ≤7 % ≤7 %
    Environmental
    Overload Limit (Shock) 5000 g pk 49050 m/s² pk
    Temperature Range -65 to +250 °F -54 to +121 °C
    Temperature Response See Graph %/°F See Graph %/°F [3]
    Enclosure Rating IP68 IP68
    Hazardous Area Approval Ex ia IIC T4, AExia IIC, T4 Ex ia IIC T4, AExia IIC, T4
    Hazardous Area Approval EEx nL IIC T4, -40 ° C ≤ Ta ≤ 121 ° C, II 1 G EEx nL IIC T4, -40 ° C ≤ Ta ≤ 121 ° C, II 1 G
    Hazardous Area Approval Cl I, Div I, Groups A, B, C, D; Cl II, Div I, Groups E, F, G; Cl III, Div I Cl I, Div I, Groups A, B, C, D; Cl II, Div I, Groups E, F, G; Cl III, Div I
    Hazardous Area Approval Cl I, Div 2, Groups A, B, C, D; ExnL IIC T4, AExnA IIC T4 Cl I, Div 2, Groups A, B, C, D; ExnL IIC T4, AExnA IIC T4
    Hazardous Area Approval EEx nL IIC 1T4, -40 = Ta = 121°C, II 3 G EEx nL IIC 1T4, -40 = Ta = 121°C, II 3 G
    Electrical
    Settling Time (within 1% of bias) ≤2 sec ≤2 sec
    Discharge Time Constant ≥0.3 sec ≥0.3 sec
    Excitation Voltage 18 to 28 VDC 18 to 28 VDC
    Constant Current Excitation 2 to 20 mA 2 to 20 mA
    Output Impedance <150 Ohm <150 Ohm
    Output Bias Voltage 8 to 12 VDC 8 to 12 VDC
    Spectral Noise (10 Hz) 8 µg/√Hz 78.5 (µm/sec2)/√Hz [3]
    Spectral Noise (100 Hz) 5 µg/√Hz 49.1 (µm/sec2)/√Hz [3]
    Spectral Noise (1 kHz) 4 µg/√Hz 39.2 (µm/sec2)/√Hz [3]
    Electrical Isolation (Case) >100000000 Ohm >100000000 Ohm
    Physical
    Size - Hex 9/16 in 14 mm
    Size - Height 0.97 in 24.6 mm
    Weight (without cable) 1.1 oz 31 gm [8]
    Mounting Stud Stud
    Mounting Thread 1/4-28 Male 1/4-28 Male [5]
    Mounting Torque (Stud) 7 to 8 ft-lb 9.5 to 10.8 Nm [6] [7]
    Mounting Torque (hex nut) 2 to 5 ft-lb 2.7 to 6.8 Nm
    Sensing Element Ceramic Ceramic
    Sensing Geometry Shear Shear
    Housing Material Stainless Steel Stainless Steel
    Sealing Welded Hermetic Welded Hermetic
    Electrical Connector Molded Integral Cable Molded Integral Cable
    Electrical Connection Position Side Side
    Cable Length 10 ft 3.0 m
    Cable Type Polyurethane Polyurethane [4]

    * All specifications are at room temperature unless otherwise specified.

    TempChart

    Accessories


    Supplied
    080A156 Swivel mounting stud, 1/2-20 to 1/4-28 stud with 1/8" hex socket for installation (for models 607A11 & 607A61) 1
    ICS-2 Calibration of industrial accel., single-point, 100 Hz reference sensitivity 1

    Optional Versions