Model : 611M10/03 | Charge Output Accelerometer

Click for lead times
$ 2,995.00 USD
(Pricing valid in US only!)

High temperature, charge mode accelerometer with UHT-12 ® shear sensing crystal, 5 pC/g sensitivity, 900 degree F, integral cable to 7/16-27 2-pin connector

Replaces Legacy Model Endevco 6235M1

  • Sensitivity: (±5%)5.0 pC/g (.510 pC/(m/s²))
  • Measurement Range: ±500 g pk (±4905 m/s² pk)
  • Weight: 14.22 oz (403.1 gm)
English: SI:
Performance
Sensitivity (±5 %) 5.0 pC/g .510 pC/(m/s²)
Measurement Range ±500 g pk ±4905 m/s² pk
Frequency Range (+10 %) 5 kHz 5 kHz [4]
Resonant Frequency 20 kHz 20 kHz [2]
Non-Linearity 1 % 1 % [1]
Transverse Sensitivity ≤5 % ≤5 % [3]
Environmental
Overload Limit (Shock) ±1000 g pk ±9810 m/s² pk
Temperature Range -65 to +900 °F -54 to +482 °C
Temperature Response See Graph %/°F See Graph %/°F [2]
Electrical
Capacitance (Pin to Pin) 240 pF 240 pF [2]
Capacitance (Pin to Case) 210 pF 210 pF [2]
Capacitance (Unbalance Between Pins) ≤2 pF ≤2 pF
Insulation Resistance (Pin to Case 70°F) >1000000000 Ohm >1000000000 Ohm [2]
Insulation Resistance (Pin to Pin 70°F) >1000000000 Ohm >1000000000 Ohm
Insulation Resistance (Pin to Pin 900°F) >100 kohm >100 kohm
Physical
Sensing Element UHT-12 UHT-12
Sensing Geometry Shear Shear
Housing Material Inconel Inconel
Sealing Hermetic Hermetic
Size - Height 0.75 in 19 mm
Size - Diameter 1.5 in 38.1 mm
Weight (with cable) 14.22 oz 403.1 gm [2]
Electrical Connector 7/16-27 2-Pin 7/16-27 2-Pin
Electrical Connection Position Side Side
Cable Length 10 ft 3.05 m
Cable Type Integral Hardline Cable Integral Hardline Cable
Mounting Through Holes (3) Through Holes (3)
* All specifications are at room temperature unless otherwise specified
.


Specification Notes


[1] Zero-based, least-squares, straight line method.
[2] Typical.
[3] Transverse sensitivity is typically <= 3%.
[4] Low frequency response is determined by external signal conditioning electronics.
[2] Typical.
[5] See PCB Declaration of Conformance PS158 for details.


Accessories


Supplied
ICS-8 Calibration, single axis amplitude response from 10 Hz to upper 10% frequency, NIST 1
081A99 Socket head cap screw, 8-32 x 0.5" long, 18-8 stainless steel 3