Log In

Log In

Need an Account? Start Here

 

Model: EX629A11A

$1,745.00 USD
(Pricing valid in US only)

Datasheet

Hazardous area approved triaxial ICP® accelerometer with 6ft integral coiled cable and configurable connector

  • Temperature Range: -40 to +176 °F (-40 to +80 °C)
  • Electrical Connector: Molded Integral Cable
  • Weight: 3.9 oz (110 gm)

Add this product to my product comparison
Compare selected models ()

 English:SI: 
Performance
Sensitivity (±10 %)100 mV/g10.2 mV/(m/s²)[1] 
Measurement Range±50 g±490.5 m/s² 
Frequency Range (3 dB) (z axis)120 to 600000 cpm2 to 10000 Hz[4][5] 
Frequency Range (3 dB) (x or y axis)120 to 420000 cpm2 to 7000 Hz 
Resonant Frequency1020 kcpm17 kHz[2] 
Broadband Resolution (1 to 10000 Hz)560 µg5694 µm/sec2[2] 
Non-Linearity±1 %±1 %[3] 
Transverse Sensitivity≤7 %≤7 % 
Environmental
Overload Limit (Shock)5000 g pk49050 m/s² pk 
Temperature Range-40 to +176 °F-40 to +80 °C 
Temperature ResponseSee Graph See Graph [2] 
Enclosure RatingIP68IP68 
Electrical
Settling Time (within 1% of bias)≤3.0 sec≤3.0 sec 
Discharge Time Constant≥0.1 sec≥0.1 sec 
Excitation Voltage18 to 28 VDC18 to 28 VDC 
Constant Current Excitation2 to 20 mA2 to 20 mA 
Output Impedance<350 Ohm<350 Ohm 
Output Bias Voltage8 to 12 VDC8 to 12 VDC 
Spectral Noise (10 Hz)40 µg/√Hz392 (µm/sec2)/√Hz[2] 
Spectral Noise (100 Hz)10 µg/√Hz98.1 (µm/sec2)/√Hz[2] 
Spectral Noise (1 kHz)6 µg/√Hz58.9 (µm/sec2)/√Hz[2] 
Electrical Isolation>100000000 Ohm>100000000 Ohm[6] 
Electrical ProtectionRFI/ESDRFI/ESD 
Physical
Size - Diameter1.49 in37.9 mm 
Size - Height0.69 in17.5 mm 
Weight (without cable)3.9 oz110 gm[2] 
MountingThrough HoleThrough Hole 
Mounting Torque (Through Bolt)2 to 5 ft-lb2.7 to 6.8 N-cm 
Sensing ElementCeramicCeramic 
Sensing GeometryShearShear 
Housing MaterialStainless SteelStainless Steel 
SealingEpoxyEpoxy 
Electrical ConnectorMolded Integral CableMolded Integral Cable 
Cable Length (Maximum Extended )6 ft1.83 m 
Cable TypePolyurethanePolyurethane 

All specifications are at room temperature unless otherwise specified.


CEceneleccsa_us

Product Notes
[1] Conversion Factor 1g = 9.81 m/s².
[2] Typical.
[3] Zero-based, least-squares, straight line method.
[4] 1Hz = 60 cpm (cycles per minute).
[5] The high frequency tolerance is accurate within ±10% of the specified frequency.
[6] Case is also isolated from cable shield at >108 ohm
[7] See PCB Declaration of Conformance PS023 for details.
Accessories:
Supplied
54101-01Mounting Bolt 10-32x.95" (Mating Guide)(1)
54102-01Locator Pin 5mm OD x 5.8mm long(1)
ICS-7NIST traceable triaxial amplitude response calibration from 10 Hz to upper +/-3dB point.(1)
Optional Versions:
No optional versions
Product Documents
Additional Downloads