Model: 352A60

$730.00 USD
(Pricing valid in US only)

High frequency, ceramic shear ICP® accel., 10 mV/g, 5 to 60k Hz, 5-44 top conn.

  • Sensitivity: (±15%) 10 mV/g (1.02 mV/(m/s²))
  • Measurement Range: ±500 g pk (±4905 m/s² pk)
  • Broadband Resolution: 0.002 g rms (0.02 m/s² rms)
  • Sensing Element: Ceramic
  • Weight: 0.21 oz (6.0 gm)

Add this product to my product comparison
Compare selected models ()

Sensitivity (±15 %)10 mV/g1.02 mV/(m/s²) 
Measurement Range±500 g pk±4905 m/s² pk[3] 
Frequency Range (±3 dB)5 to 60000 Hz5 to 60000 Hz 
Electrical Filter Corner Frequency45 kHz45 kHz[5] 
Electrical Filter Roll-off10 dB/decade10 dB/decade[5] 
Resonant Frequency≥95 kHz≥95 kHz 
Broadband Resolution (1 to 10000 Hz)0.002 g rms0.02 m/s² rms[4] 
Non-Linearity≤1 %≤1 %[1] 
Transverse Sensitivity≤5 %≤5 %[2] 
Overload Limit (Shock)±5000 g pk±49050 m/s² pk 
Temperature Range-65 to 250 °F-54 to +121 °C 
Temperature ResponseSee Graph %/°FSee Graph %/°F[4] 
Base Strain Sensitivity≤0.05 g/µε≤0.49 (m/s²)/µε[4] 
Excitation Voltage18 to 30 VDC18 to 30 VDC 
Constant Current Excitation2 to 20 mA2 to 20 mA[3] 
Output Impedance≤100 Ohm≤100 Ohm 
Output Bias Voltage8 to 12 VDC8 to 12 VDC 
Discharge Time Constant0.02 to 0.06 sec0.02 to 0.06 sec[5] 
Spectral Noise (10 Hz)160 µg/√Hz1570 (µm/sec2)/√Hz[4] 
Spectral Noise (100 Hz)40 µg/√Hz390 (µm/sec2)/√Hz[4] 
Spectral Noise (1 kHz)15 µg/√Hz147 (µm/sec2)/√Hz[4] 
Spectral Noise (10 kHz)10 µg/√Hz98 (µm/sec2)/√Hz[4] 
Size - Height0.81 in21.6 mm 
Weight0.21 oz6.0 gm[4] 
Sensing ElementCeramicCeramic 
Size - Hex3/8 in3/8 in 
Sensing GeometryShearShear 
Housing MaterialStainless SteelStainless Steel 
SealingWelded HermeticWelded Hermetic 
Electrical Connector5-44 Coaxial5-44 Coaxial 
Electrical Connection PositionTopTop 
MountingIntegral StudIntegral Stud 
Mounting Thread10-32 Male10-32 Male 

All specifications are at room temperature unless otherwise specified.


Product Notes
[1] Zero-based, least-squares, straight line method.
[2] Transverse sensitivity is typically <= 3%.
[3] >6 mA excitation current required when driving cables longer than 50 ft (15.2 m) to avoid distortion and maintain full range
[4] Typical.
[5] Calculated.
[6] See PCB Declaration of Conformance PS023 for details.
ACS-52Single axis amplitude response calibration from -3 dB to +3 dB frequency range(1)
Optional Versions:
(A) Adhesive Mount
    Mounting ThreadNone - Adhesive Mount Only
    Size - Hex3/8
    Size - Height0.68 17.3
    080A90Quick Bonding Gel(1)
(M) Metric Mount
    Mounting ThreadM6 x 0.75 Male
Product Documents