| Performance |
| Alarm Threshold (±10 %) |
0.25 to 5 in/sec pk |
4.5 to 90 mm/s rms |
[1]
|
| Frequency Range (±3 dB) |
420 to 60 kcpm |
7 to 1000 Hz |
|
| Hysteresis (% < Alarm Threshold) |
3; 6; or 10 % |
3; 6; or 10 % |
[1]
|
| Residual Vibration Level (Reference) |
Dependent or Independent |
Dependent or Independent |
[1]
|
| Residual Vibration Level (% Alarm Threshold) |
1 to 40 % |
1 to 40 % |
[1]
|
| MAVT (Sets Alarm Threshold to 2X actual vibration) |
Enabled or Disabled |
Enabled or Disabled |
[1]
|
| Transverse Sensitivity |
<3 % |
<3 % |
|
| Power On Delay (±1 sec) |
3 or 20 sec |
3 or 20 sec |
[1]
|
| Startup Delay (±1 sec or 1 min ) (Time) |
1 to 60 sec or 1 to 30 min |
1 to 60 sec or 1 to 30 min |
[1]
|
| Startup Delay (x Alarm Threshold) |
x2; x4; x8; Blocked |
x2; x4; x8; Blocked |
[1]
|
| Startup Delay (Active) |
Enabled or Disabled |
Enabled or Disabled |
[1]
|
| Operational Delay (±1 sec) |
1 to 60 sec |
1 to 60 sec |
[1]
|
| Relay(Type) |
SPST, Form A or B MOSFET |
SPST, Form A or B MOSFET |
|
| Relay(Capacity) |
24 to 240 V AC/DC, 500 mA |
24 to 240 V AC/DC, 500 mA |
|
| Relay(Latching) |
Latching / Non-Latching |
Latching / Non-Latching |
[1]
|
| Relay(Contacts) |
Normally Open / Closed |
Normally Open / Closed |
[1]
|
| Environmental |
| Temperature Range (Operating) |
-40 to 185 °F |
-40 to 85 °C |
|
| Temperature Range (Storage) |
-40 to 257 °F |
-40 to 125 °C |
|
| Overload Limit (Shock) |
5000 g pk |
49050 m/s² pk |
|
| Electrical |
| Power Required |
24 to 240 V DC/AC 50/60 Hz |
24 to 240 V DC/AC 50/60 Hz |
|
| Current Rating (Relay Closed) |
500 mA |
500 mA |
|
| Leak Current (Relay Open) |
≤1 mA |
≤1 mA |
|
| Electrical Isolation (Case) |
>100000000 Ohm |
>100000000 Ohm |
|
| Physical |
| Size - Hex |
1.38 in |
1.38 in |
|
| Size - Height |
3.68 in |
94 mm |
|
| Weight |
7.0 oz |
200 gm |
|
| Mounting Thread |
1/4 NPT |
No Metric Equivalent |
|
| Sensing Element (Internal) |
Piezoelectric Accelerometer |
Piezoelectric Accelerometer |
|
| Housing Material |
Stainless Steel |
Stainless Steel |
|
| Electrical Connector |
Terminal Block |
Terminal Block |
|
| Electrical Connection Position |
Top |
Top |
|
| Screw Terminal Wire Size |
12-24 AWG |
3.0 - .2mm² |
|
| Conduit Housing Thread |
1" NPT Female |
No Metric Equivalent |
|