| Performance |
| Number of Conductors |
2 |
2 |
|
| Cable Style |
Multi Conductor - Shielded |
Multi Conductor - Shielded |
|
| Cable Configuration |
Twisted Pair |
Twisted Pair |
|
| Environmental |
| Temperature Range |
-90 to +392 °F |
-70 to +200 °C |
|
| Electrical |
| Capacitance (conductor to conductor @ 70 °F (21 °C)) |
35 pF/ft |
114.8 pF/m |
[1]
|
| Capacitance (conductor to shield / drain @ 70 °F (21 °C)) |
67 pF/ft |
219.8 pF/m |
[1]
|
| Physical |
| Cable Jacket Diameter |
0.119 in |
3.02 mm |
[1]
|
| Cable Jacket Material |
FEP |
FEP |
|
| Cable Jacket Color |
Red |
Red |
|
| Protective Covering Diameter (±10 %) |
.129 in |
3.28 mm |
[2]
|
| Protective Covering |
Steel Braid |
Steel Braid |
|
| Conductor Style |
Stranded - 7 Strands 30 AWG |
Stranded - 7 Strands 30 AWG |
|
| Conductor Material |
Tin Plated Copper |
Tin Plated Copper |
|
| Conductor Diameter (22 AWG) |
0.025 in |
0.635 mm |
[1]
|
| Insulation Material Over Conductor(s) |
FEP |
FEP |
|
| Shield Type Over Bundle |
Foil |
Foil |
|
| Shield Material Over Bundle |
Aluminum / Mylar |
Aluminum / Mylar |
|
| Drain Wire Material |
Tin Plated Copper |
Tin Plated Copper |
|
| Drain Wire Diameter (22 AWG) |
0.025 in |
0.635 mm |
[1]
|
| Bend Radius (minimum) |
2 in |
50.8 mm |
|
| Weight |
0.328 oz/ft |
30.51 gm/m |
[1]
|
| ROHS Compliant |
Yes |
Yes |
|