Performance |
Measurement Range |
0 to 1.5 in/sec pk |
0 to 38.1 mm/s pk |
|
Frequency Range (±3 dB) |
120 to 60000 cpm |
2 to 1000 Hz |
[1]
|
Power On Delay |
20 sec |
20 sec |
[2]
|
Relay (Alert) |
10A/245 VAC or 5A/30 VDC |
10A/245 VAC or 5A/30 VDC |
|
Relay (Alarm) |
10A/245 VAC or 5A/30 VDC |
10A/245 VAC or 5A/30 VDC |
|
Relay(Contacts) |
Latching / Non-Latching |
Latching / Non-Latching |
|
Relay(Contacts) |
Normally Open / Closed |
Normally Open / Closed |
|
Alarm Setpoint |
10 to 100% of Vibration Range |
10 to 100% of Vibration Range |
|
Alert Setpoint |
10 to 100% of Alarm Setpoint |
10 to 100% of Alarm Setpoint |
|
Delay (Alert) |
0 to 45 sec |
0 to 45 sec |
|
Delay (Alarm) |
0 to 45 sec |
0 to 45 sec |
|
Acceleration Output (±10 %) |
100 mV/g |
10.2 mV/(m/s²) |
|
Control Interface |
Power LED |
Green |
Green |
|
Alarm LED |
Red |
Red |
|
Alert LED |
Yellow |
Yellow |
|
Time Delay Adjustment |
Single Turn Potentiometer |
Single Turn Potentiometer |
|
Reset Function |
Momentary Pushbutton Switch |
Momentary Pushbutton Switch |
[3]
|
Self Test Function |
Momentary Pushbutton Switch |
Momentary Pushbutton Switch |
|
Environmental |
Temperature Range (Operating) |
-13 to 158 °F |
-25 to 70 °C |
|
Temperature Range (Storage) |
-40 to 257 °F |
-40 to 125 °C |
|
Hazardous Area Approval |
Class I Div 1 Groups B, C, D |
Class I Div 1 Groups B, C, D |
|
Hazardous Area Approval |
Class II Div 1 Groups E, F, G |
Class II Div 1 Groups E, F, G |
|
Hazardous Area Approval |
Class III |
Class III |
|
Enclosure Rating |
Nema 4X |
IP66 |
|
Electrical |
Power Required |
85-245 VAC 50/60 Hz |
85-245 VAC 50/60 Hz |
|
Current Consumption |
<150 mA |
<150 mA |
|
Output Current |
4 to 20 mA |
4 to 20 mA |
[4]
|
External Calibration Input |
4 to 20 mA |
4 to 20 mA |
[5]
|
Physical |
Size - Width |
4.48 in |
114 mm |
|
Size - Height |
4.58 in |
116 mm |
|
Size - Depth |
4.48 in |
114 mm |
|
Weight |
4 lb |
1.8 kg |
|
Mounting Torque (Base) |
2 to 5 ft-lb |
3 to 7 Nm |
|
Sensing Element (Internal) |
100 mV/g ICP" Accelerometer |
100 mV/g ICP" Accelerometer |
|
Housing Material |
Aluminum Alloy |
Aluminum Alloy |
|
Electrical Connector |
Screw Terminals |
Screw Terminals |
|
Enclosure |
Internal and Remote Reset |
Internal and Remote Reset |
|
Screw Terminal Wire Size |
24-14 AWG |
0.2 - 2.5 mm² |
|
Cable Input |
Dual 1/2 in. NPT Conduit Hubs |
Dual 1/2 in. NPT Conduit Hubs |
|
Mounting Hole Size |
0.31 in |
7.8 mm |
|