rocket motor icp® pressure sensor, 250 psi, 20 mv/psi, helium bleed, water-cooled with safety wire holes and replaceable cooling tubes.

PRESSURE SENSOR

Model 123B21

Retrieving Price...

(Pricing valid only in the U.S.)

Units in Stock Lead Times
More on the way Call for Lead Time
  • CE
  • IP

Rocket motor ICP® pressure sensor, 250 psi, 20 mV/psi, Helium bleed, water-cooled with safety wire holes and replaceable cooling tubes.

  • Measurement Range: 250 psi (1724 kPa)
  • Sensitivity: (±15%)20 mV/psi (2.90 mV/kPa)
  • Low Frequency Response: (-5%)0.5 Hz
  • Resonant Frequency: >=25 kHz (>=25 kHz)
  • Electrical Connector: Integral Cable
  • Weight: 4.59 oz (130 gm)

Specification Notes


[1] Zero-based, least-squares, straight line method.
[2] Typical.
[3] For +10 volt output, minimum 24 VDC supply voltage required. Negative 10 volt output may be limited by output bias.
[4] With helium flow.
[2] Typical.
[5] Applies to internal amplifer, not to external housing.
[6] See PCB Declaration of Conformance PS023 for details.

English: SI:
Performance
Measurement Range (for ±5V output) 250 psi 1724 kPa
Useful Overrange (for ± 10V output) 500 psi 3448 kPa [3]
Sensitivity (±15 %) 20 mV/psi 2.90 mV/kPa
Maximum Pressure 5000 psi 34475 kPa
Resolution 0.005 psi 0.034 kPa [2]
Resonant Frequency ≥25 kHz ≥25 kHz [4]
Rise Time (Reflected) ≤20 µ sec ≤20 µ sec [4]
Low Frequency Response (-5 %) 0.5 Hz 0.5 Hz
Non-Linearity ≤1.0 % FS ≤1.0 % FS [1]
Environmental
Acceleration Sensitivity 0.002 psi/g 0.0014 kPa/(m/s²) [2]
Temperature Range (Operating) -100 to +250 °F -73 to +121 °C [5]
Temperature Coefficient of Sensitivity ≤0.03 %/°F ≤0.054 %/°C
Maximum Flash Temperature 10000 5538 °C
Maximum Vibration 2000 19600 m/s² pk
Maximum Shock 10000 g pk 98070 m/s² pk
Electrical
Output Polarity (Positive Pressure) Positive Positive
Discharge Time Constant ≥1 sec ≥1 sec
Excitation Voltage 20 to 30 VDC 20 to 30 VDC
Constant Current Excitation 2 to 20 mA 2 to 20 mA
Output Impedance ≤100 Ohm ≤100 Ohm
Output Bias Voltage 8 to 14 VDC 8 to 14 VDC
Physical
Housing Material 17-4 Stainless Steel 17-4 Stainless Steel
Diaphragm Invar Invar
Sealing Hermetic Hermetic
Electrical Connector Integral Cable Integral Cable
Weight 4.59 oz 130 gm
Helium Flow Rate (at 1,500 psi) 40 scf/hr 1.13 m³/hr
Water Flow Rate (at 50 psi) 1.2 gal/min 4.5 L/min
Cable Length 4 ft 1.2 m

* All specifications are at room temperature unless otherwise specified.

Accessories


Supplied
PCS-5 Calibration of Series 113B50, 122A, 123A, & 124A 0
070A08 Cable adaptor (10-32 jack to BNC jack) 1
065A72 Replacement cooling tubes, set of 2 each, with o-rings, for series 123B 2
065A15 Seal, 0.624" OD x 0.553" ID x 0.080" thk, brass (for Series M121Axx & 123A) 3