Model : 607M141 | Industrial ICP® Accelerometer

Call for lead time
$ 315.00 USD
(Pricing valid in US only!)

Low profile ind ICP accel, 100mV/g. 0.4 to 14k Hz, 10ft armor cable w/ blunt cut & swiv base, single point calibration, extra RF protection.

  • Sensitivity: (±10%)100 mV/g (10.2 mV/(m/s²))
  • Frequency Range: (±3dB)24 to 840000 cpm (0.4 to 14000 Hz)
  • Sensing Element: Ceramic
  • Measurement Range: ±80 g (±785 m/s²)
  • Weight: 1.1 oz (31 gm)
Additional Configurations:
English: SI:
Performance
Sensitivity (±10 %) 100 mV/g 10.2 mV/(m/s²) [1]
Measurement Range ±80 g ±785 m/s²
Frequency Range (±3 dB) 24 to 840000 cpm 0.4 to 14000 Hz
Resonant Frequency 1500 kcpm 25 kHz [3]
Broadband Resolution (1) 550 µg 5395 µm/sec2 [3]
Non-Linearity 1 % 1 % [2]
Transverse Sensitivity ≤7 % ≤7 %
Environmental
Overload Limit (Shock) 5000 g pk 49050 m/s² pk
Temperature Range -65 to +250 °F -54 to +121 °C
Temperature Response See Graph %/°F See Graph %/°F [3]
Enclosure Rating IP67 IP67
Electrical
Settling Time (within 1% of bias) ≤2 sec ≤2 sec
Discharge Time Constant ≥0.4 sec ≥0.4 sec
Excitation Voltage 24 to 28 VDC 24 to 28 VDC
Constant Current Excitation 2 to 20 mA 2 to 20 mA
Output Impedance <150 Ohm <150 Ohm
Output Bias Voltage 10 to 14 VDC 10 to 14 VDC
Spectral Noise (10 Hz) 10 µg/√Hz 78.5 (µm/sec2)/√Hz [3]
Spectral Noise (100 Hz) 7 µg/√Hz 49.1 (µm/sec2)/√Hz [3]
Spectral Noise (1 kHz) 7 µg/√Hz 39.2 (µm/sec2)/√Hz [3]
Electrical Isolation (Case) >100000000 Ohm >100000000 Ohm
Physical
Size - Hex 9/16 in 14 mm
Size - Height 1.0 in 25.4 mm
Weight (without cable) 1.1 oz 31 gm [6]
Mounting Stud Stud
Mounting Thread 1/4-28 Male 1/4-28 Male [4]
Mounting Torque (Stud) 3 to 4 ft-lb 4.1 to 5.4 Nm [5] [8]
Mounting Torque (hex nut) 2 to 3 ft-lb 2.7 to 4.1 Nm
Sensing Element Ceramic Ceramic
Sensing Geometry Shear Shear
Housing Material Stainless Steel Stainless Steel
Sealing Welded Hermetic Welded Hermetic
Electrical Connector Integral Armored Cable Integral Armored Cable
Electrical Connection Position Side Side
Cable Length 10 ft 3.0 m
Cable Type Polyurethane Polyurethane [7]
* All specifications are at room temperature unless otherwise specified
.


Specification Notes


[1] Conversion Factor 1g = 9.81 m/s².
[2] Zero-based, least-squares, straight line method.
[3] Typical.
[4] 1/4-28 has no equivalent in S.I. units.
[5] Stud torque must exceed sensor hex nut torque to ensure proper dismantling.
[6] Measured with mounting stud.
[7] Stainless steel armor jacket over twisted shielded pair.
[8] 1/8" hex Allen key required for English version, 3mm hex Allen key required for metric version.
[9] See PCB Declaration of Conformance PS023 for details.


Accessories


Supplied
ICS-2 Calibration of industrial accel., single-point, 100 Hz reference sensitivity 1
080A156 Swivel mounting stud, 1/2-20 to 1/4-28 stud with 1/8" hex socket for installation (for models 607A11 & 607A61) 1