miniature (0.6 gm) charge output accel., 1.7 pc/g, 10k hz, titanium housing, 10-ft detachable cable

Accelerometer, Charge Output

Model 357A09

  • CE
  • IP

Miniature (0.6 gm) charge output accel., 1.7 pC/g, 10k Hz, titanium housing, 10-ft detachable cable

  • Sensitivity: (±20%)1.7 pC/g (0.17 pC/(m/s²))
  • Measurement Range: ±2000 g pk (±19620 m/s² pk)
  • Frequency Range: (+5%)10000 Hz
  • Weight: 0.02 oz (0.6 gm)

Specification Notes


[1] Zero-based, least-squares, straight line method.
[2] Transverse sensitivity is typically ≤ 3%.
[3] Low frequency response is determined by external signal conditioning electronics.
[4] Typical.
[5] See PCB Declaration of Conformance PS081 for details.

English: SI:
Performance
Sensitivity (±20 %) 1.7 pC/g 0.17 pC/(m/s²)
Measurement Range ±2000 g pk ±19620 m/s² pk
Frequency Range (+5 %) 10000 Hz 10000 Hz [3]
Frequency Range (+10 %) 13000 Hz 13000 Hz [3]
Resonant Frequency ≥50 kHz ≥50 kHz
Non-Linearity ≤1 % ≤1 % [1]
Transverse Sensitivity ≤5 % ≤5 % [2]
Environmental
Overload Limit (Shock) ±10000 g pk ±98100 m/s² pk
Temperature Range -100 to +350 °F -73 to +177 °C
Temperature Response See Graph %/°F See Graph %/°F [4]
Base Strain Sensitivity ≤0.10 g/µε ≤1.0 (m/s²)/µε [4]
Electrical
Capacitance 310 pF 310 pF [4]
Insulation Resistance (at 70° F [21°C]) >10000000000 Ohm >10000000000 Ohm
Output Polarity Negative Negative
Physical
Sensing Element Ceramic Ceramic
Sensing Geometry Shear Shear
Housing Material Titanium Titanium
Sealing Epoxy Epoxy
Size - Height 0.14 in 3.6 mm
Size - Length 0.45 in 11.4 mm
Size - Width 0.25 in 6.4 mm
Weight 0.02 oz 0.6 gm [4]
Electrical Connector 3-56 Coaxial Jack 3-56 Coaxial Jack
Electrical Connection Position Side Side
Mounting Adhesive Adhesive

* All specifications are at room temperature unless otherwise specified.

TempChart

Accessories


Supplied
030A10 Miniature, low-noise, blue coaxial cable, 10-ft, 3-56 plug to 10-32 plug 1
039A27 Removal tool (for Models 352A21, 352C22, 357A09, 357C10 & 352A25) 1
080A109 Petro Wax, one square, 1" x 1" x 0.25" 1
ACS-1 Single axis amplitude response calibration from 10 Hz to upper 5% frequency, NIST traceable 1

Optional Versions