641B11  alternate_photo Industrial monitoring Instrumentation

Model 641B11
Product Type: Accelerometer, Vibration Sensor, Vibration Transmitter
Industrial vibration sensor, 4 to 20 mA output, 0 to 1 in/sec RMS, 10 to 1k Hz, top exit, 10-ft integral cable
View Spec Sheet (PDF)
View photo and drawing .
PERFORMANCE ENGLISH SI
Measurement Range 0.0 to 1 in/sec rms
0.0 to 25.4 mm/s rms [1][2]
Output 4-20 mA
4-20 mA
Frequency Range(± 10 %) 600 to 60,000 cpm
10 to 1 kHz [3][4]
Broadband Resolution 0.005 in/sec rms
0.13 mm/s rms [5]
Non-Linearity ± 1 %
± 1 %
ENVIRONMENTAL
Temperature Range -40 to 185 °F
-40 to 85 °C
ELECTRICAL
Excitation Voltage 12 to 30 VDC
12 to 30 VDC
Settling Time(within 2% of value) <15 sec
<15 sec
Electrical Isolation(Case) >108 ohm
>108 ohm
PHYSICAL
Size (Hex x Height) 1.0 in x 4.2 in
25.4 mm x 107 mm
Weight(without cable) 4.7 oz
131 gm
Mounting Thread 1/4-28 UNF
No Metric Equivalent
Mounting Torque 3 to 5 ft-lb
4 to 7 N-m
Sensing Element Ceramic
Ceramic
Sensing Geometry Shear
Shear
Housing Material Stainless Steel
Stainless Steel
Sealing Welded Hermetic
Welded Hermetic
Electrical Connector Integral Cable
Integral Cable
Electrical Connection Position Top
Top
Electrical Connections(Red) 4-20 mA Pos (+)
4-20 mA Pos (+)
Electrical Connections(Blue) 4-20 mA Neg (-)
4-20 mA Neg (-)
Cable Length 10 ft
3.0 m
Cable Type Polyurethane
Polyurethane
SUPPLIED ACCESSORIES:
Model 081A40 Mounting Stud (1)
Model ICS-4 NIST-traceable single-axis amplitude response calibration from 0 cpm (0 Hz) to upper 10% frequency for 4 - 20 mA output vibration sensor (1)
OPTIONAL VERSIONS
EX- Hazardous Area Approval- contact factory for specific approvals
Hazardous Area Approval DIV II, CL I, GRPS A-D, ExnL, AExnA, IIC T4
Hazardous Area Approval EEx ia IIC T4, -196°C≤Ta≤121°C, II 1 G
Hazardous Area Approval EEx nL IIC T4, -40°C≤Ta≤80°C, II 3 G
Hazardous Area Approval DIV I, CL I, II, III, GRPS A-G, Exia, AExia, IIC T4
M- Metric Mount
Supplied Accessory : Model M081A61 Mounting Stud 1/4-28 to M6 X 1 (1) replaces Model 081A40
RV- Buffered Analog Signal Output - 100 mV/g (±20%)
Electrical Connector Integral Cable
Electrical Connections(Red) 4-20 mA Pos (+)
Electrical Connections(Black) 4-20 mA Neg (-)
Electrical Connections(White) Signal Output Pos
Electrical Connections(Green) Signal Output Neg

All specifications are at room temperature unless otherwise specified.
NOTES:
[1]Conversion Factor 1 in/sec = 0.0254 m/sec.
[2]Maximum frequency for 1 in/sec rms output, 700 Hz.
[3]Current will fluctuate at frequencies below 5 Hz.
[4]1Hz = 60 cpm (cycles per minute).
[5]Typical.
[6]See PCB Declaration of Conformance PS039 or PS053 for details.



[6]



641B11  alternate_photo



Download Drawing 27348-NR.pdf
Top