Log In

Log In

Need an Account? Start Here

 

Model: 1631-06C

$373.50 USD
(Pricing valid in US only)


PCB L&T S-Type Load Cell, 5,000 lbf rated capacity, 150% of RO static overload protection, 2mV/V output, 5/8-18 UNF threads, integral 10 ft cable w/ open end, nickel-plated steel

  • Measurement Range: 5000 lb (22.2 kN)
  • Size - Height: 3.50 in (89 mm)
  • Electrical Connector: 10 ft - Integrated Cable

Add this product to my product comparison
Compare selected models ()

 English:SI: 
Performance
Measurement Range5000 lb22.2 kN[1] 
Sensitivity (±10 %)2 mV/V2 mV/V[2] 
Non-Linearity≤0.05 % FS≤0.05 % FS 
Hysteresis≤0.03 % FS≤0.03 % FS 
Non-Repeatability≤0.02 %RO≤0.02 %RO 
Resonant Frequency2.5 kHz2.5 kHz 
Creep (in 20 minutes)≤0.08 %≤0.08 % 
Environmental
Overload Limit7500 lb33.4 kN 
Load Limit (Side Force, FX or FY)500 lb2224 N[4] 
Load Limit (Bending Moment, MX or MY)1250 in-lb141.2 Nm[4] 
Load Limit (Axial Torque, MZ)1250 in-lb141.2 Nm[4] 
Temperature Range (Operating)0 to +200 °F-18 to +93 °C 
Temperature Range (Compensated)+70 to +170 °F+21 to +77 °C 
Temperature Effect on Output (Maximum)±0.0008 %Reading/°F±0.0015 %Reading/°C[3] 
Temperature Effect on Zero Balance (Maximum)±0.0015 %FS/°F±0.027 %FS/°C[3] 
Electrical
Bridge Resistance350 Ohm350 Ohm[6] 
Excitation Voltage (Recommended)10 VDC10 VDC[5] 
Insulation Resistance>5000000000 Ohm>5000000000 Ohm 
Zero Balance±1 % FS±1 % FS 
Output Polarity+Tension +Tension  
Physical
Size - Height3.50 in89 mm 
Size - Width1.50 in38 mm 
Size - Length2.50 in64 mm[7] 
Weight2.85 lb1.3 g 
Mounting Thread5/8-18 ThreadNo Metric Equivalent 
Housing MaterialNickel Plated SteelNickel Plated Steel 
Sensing ElementStrain GageStrain Gage 
Deflection at Full Scale Capacity0.003 in0.05 mm 
Electrical Connector10 ft - Integrated Cable10 ft - Integrated Cable 
Electrical Connection PositionSideSide 

All specifications are at room temperature unless otherwise specified.



Product Notes
[1] FS - Full Scale.
[2] RO - Rated Output.
[3] Over compensated operating temperature range.
[4] Singularly applied, i.e. no other extraneous loads.
[5] Calibrated at 10 VDC, usable 5 to 20 VDC or VAC RMS.
[6] Nominal.
[7] See Outline Drawing 46138 for Complete Dimensions
Accessories:
No Accessories
Optional Versions:
No optional versions
Product Documents
Additional Downloads